800 370 0820
The Highest Quality Custom Infrared Saunas
Exterior Width: 8 feet (front-facing side with glass doors)
Exterior Depth: 6 feet (side profile from wall to front)
Exterior Height: 8 feet (floor to top of roof)
Roof Overhang (Front): 9 feet wide total (1/2 foot overhang on each side)
Roof Overhang (Depth): 2 feet beyond the front wall
Wall Cladding: Vertical black wood paneling
Roof: Flat with recessed lighting and snow load capability
Interior Width: 7 feet (measured wall-to-wall along the front/glass door side)
Interior Depth: 5 feet (measured from the back wall to the inside face of the glass doors)
Interior Height: 7 feet (floor to interior ceiling)
Lighting: Warm amber LED lighting recessed in ceiling and beneath benches
Wall Finish: Alternating vertical Western Red Cedar slats and black carbon heater panels
Flooring: Tongue-and-groove clear cedar with natural variation in tone
Total Power Draw: 12,000 watts (12 kW)
Voltage: 240 volts
Amperage: 50 amps
Power Phase: Single-phase
Circuit Requirement: Dedicated 50-amp breaker
Wiring: 6-gauge copper wire recommended for 50-amp load
Connection Type: Hardwired (no plug)
Disconnect: Outdoor-rated spa disconnect or subpanel recommended near the unit
GFCI Protection: Required by code for outdoor installations
Installation Note: Must be installed by a licensed electrician in accordance with local electrical codes